Public Safety Awareness Over Medical Gas & Medical / Surgical Area Alarm Panels.
We need to educate everyone that Allied Healthcare Products
( Chemetron Area Medical Gas and Vacuum Alarm Panels )
Does Not Meet NFPA 99 2012 Edition Code Section #5.1.9.3.5
Area alarm panels for medical gas systems shall provide visual and audible indication in the event a mismatch occurs between the transducer(s) and its associated circuit board(s).
NOTE:
CMS Has Approved and Adopted the NFPA 99 for the 2012 Edition Starting July 01, 2016. ? What does you State A H J Require ?
Chemetron management has indicated that this product (Impact Series Area Alarm Panel #74-15-xxx) does not meet NFPA 99 for the 2012 Edition. (i.e. no visual and audible indication in the event a mismatch occurs between the transducer(s) and its associated circuit board(s).